Alia Variable Area Flowmeters
AVF250 Series
ALIAVA AVF250 Series is a flowmetercommonly used in Auto-industry process control. It’s with small volume, wide range and easily operation. It could also measure liquid, gas and steam flowrate, especially fit for small flowrate application.
FEATURES
4 digit flowrate & 8 digit totalizer Local indication without auxiliary power 4-20 mA & Scale pulse output Low pressure lost on gas and steam application Damper for Gas/Steam application Consistent overall length Heating jacket design Intrinsically safe & explosion proof for hazardous area
SPECIFICATION
Size:Local Display:
15,20,25,40,50,65,80,100,125,150,200 mmMechanical Indicator (standard)
Measuring Range:Digit Display
Liquid – 1 ~ 200000 Liter/Hr4 Digit Flowrate
Gas – 0.03 ~ 4000 M3/Hr8 Digit Totalizer
Turndown Ratio:Current output:
10:1 (20:1 Optional)4-20 mA(2 Wire)
Accuracy:Load
+/-1.6%(Standard)Max. 600
+/-1.0%(Optional)Pulse output:
Repeatability:Open collector (Scale pulse)
+/-0.5% value of readingRating
Material:3 to 30Vdc, 100 mA Max.
Tube & FloatData Storage:
Stainless Steel 304Operation parameters and totalization
Stainless Steel 316figures are stored by EEPROM for more
Stainless Steel 316Lthan 10 years
Stainless Steel + PTFE LinerAlarm output:
Standard Pressure:2 point (open collector)
40 Kg/cm2 (15mm ~ 50mm)Rating
16 Kg/cm2 (65mm ~ 200mm)3 to 30Vdc, 100 mA Max.
Temperature:Keyboard:
-80 ~ +200oC (Standard)
3 keys from internal for programming
-25 ~ +100oC (LCD Display)
and display control.
0 ~ +85 oC (PTFE Liner)
Ambient temperature:
-80 ~ +400oC (Optional)
-25 to +60oC
Flange Type:Protection class:
JIS 10K / JIS 20K / JIS 40KIP 65
ANSI 150# / ANSI 300# / ANSI 600#Intrinsically Safe, Eex ia IIC T5
DIN PN 10 / PN 16 / PN25 / PN 40Explosion Proof, Ex d IIB T6
Fluid Viscosity:Housing Material:
300 CP Max.Aluminum Alloy
Communication:Cable entry:
RS485(MODBUS Protocol)M20 * 1.5
HART SignalPressure Drop:
0.07 ~ 0.7 Kg/cm2
Power supply:
11 ~ 36VDC( 2 wire 4-20 mA)
Ni-MH Battery(3 years working hours)