top of page

Alia Electromagnetic Flow Meter


AMF601 Series

AMF601 Series is a sanitary type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 25mm to 100 mm. The AMF601 is widely used for drink water, milk, food & beverage juice and many other industrial fluid. AMF601 Series electromagnetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic flowmeter.

FEATURES

Light and compact version Flow Velocity range: 0-12 m/s, precise in low flow applications IDF Tri-Clamp or Union screw Connection Excellent for high pressure application Protection class: IP68 available; sensor submersible PTFE Liner is suitable for vacuum tube High accuracy of +/-0.4% value of reading (or+/-0.2% value of reading) With Forward / Reverse flowrate measurement function

SPECIFICATION

Size:Cable Entry:

25, 32, 40, 50, 65, 80, 100 mmStandard :PG11 Option:1/2"NPTF

1", 1-1/4", 1-1/2", 2", 2-1/2", 3" , 4"Ambient Temperature:

Measuring Range:

-25 to +60 oC

Velocity 0-0.25 m/s min.Process Connection:

0-12 m/s max.IDF Tri-Clamp

Material:Union Screw

Tube & ConnectionGrounding Resistance:

Stainless Steel 304 or 316Must be less than 10

Coil HousingAccuracy:

Stainless Steel 304 (Standard)+/-0.5% reading (Velocity >=0.5m/s)

Stainless Steel 316 (Option)+/-0.2% reading

Liner(Suitable for AMC3200/3200E converter only)

PTFE+/-0.0025 m/s (Velocity < 0.5 m/s)

ElectrodeTemperature:

Stainless Steel 316L

-40 to +150 oC

Hastelloy BMax. Pressure:

Hastelloy C10 Kg/cm2 (Standard)

Titanium40 Kg/cm2 (Option)

TantalumExplosion Proof:

Tungsten CarbideExd(ib)ibqIIBT5

Platinum(with AMC3200 only)

Protection Class:

Junction box IP67, Body IP68

IP68 (Submersible)

Conductivity:

More than 5 uS/cm

AMC2100 Series

The Aliamag AMC2100 series converter is a microprocessor based intelligent transmitter that can be paired with any of the Alia AMF series sensors. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting.

FEATURES

Three line LCD display Flow Rate / Totalizer Accuracy of +/-0.4% value of reading Bi-directional flow measurement, current and pulse output Large digital display Records up to 99 power on/off time MODBUS/HART communication

SPECIFICATION

Excitation:Keyboard:

DC pulsed3 external keys for programming

Display:and display control

3 lines LCD with illuminationLow Flow Cutoff:

Line 10 to 9.9 %

11 digit totalizer for forward flowData logger Function:

11 digit totalizer for reverse flow99 times flowrate records for power on/off

11 digit totalizer for differenceRecord Data:

Line 2Date/Time when Power on/off

5 digit flowrate / velocity / % / mA / HZFlow rate when Power on/off

Line 3Totalizer when Power on/off

Parameter / Query / Clr tot / Query LOGDamping:

Alarm, Guidance0 to 99 Seconds

UnitDensity Setting:

M3/H, L/H, Kg/H, T/H, L/min, M3/min, GPH0.1 to 9.99 g/cm3

GPM, ML/H, ML/m, ML/secSelf Diagnosis:

Measuring Range:The following error message are

Min. 0 to 0.15 m/sdisplayed if failure occurs

Max. 0 to 15 m/s- Coil failure

Accuracy:- Power failure

+/-0.4% read-out values (Velocity >=0.5 m/s)- Overranged output

+/-0.002 m/s (Velocity < 0.5 m/s)- Internal error

Repeatability:- Overflow

+/-0.1% read-out values- Empty pipe

Current Output:Cable Entry:

4-20 mA (Isolated)Standard :PG11 Option:1/2"NPTF

LoadProtection Class:

Max. 600 IP 65

Pulse output:Ambient Temperature:

Open collector

-25 to +65 oC

RatingMaterial:

3 to 30 VDC, 20 mA Max. Aluminum Alloy

Pulse Rate:Power Supply:

1)Scale pulse (Pusle/M3, Pulse/L, Other)90-260 VAC, 50/60 Hz

2)Frequency: 0-5000 Hz24VDC +/-10% (Option)

Pulse Width:Power Consumption:

50% of band width3-17 W (Dependent on sensor size)

Alarm:Weight:

High/Low with open collector output1.4 Kg

RatingMounting:

3 to 30 VDC, 20 mA Max. Wall mounting

Communication:Bracket on 2" pipe

RS 485 (MODBUS Protocol)

HART signal (Compatible)

Data Storage:

Operation parameters and totalizer

figures are stored by EEPROM for more

than 10 years

AMF900 Series

AMF900 Series is a flange type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 10A to 2000mm. AMF900 is widely used for sewage, industrial waste, chemical, solvent, food & beverage, pulp & paper and many other industrial fluid. AMF900 Series electromagnetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic flowmeter.

FEATURES

Various liner and electrode satisfy most industrial applications Flow Velocity range: 0-12 m/s, precise in low flow applications It comes any flanges such as, ANSI, DIN, JIS... etc Excellent for high pressure application Protection class: IP68 available; sensor submersible FEP Liner is suitable for vacuum tube High accuracy of +/-0.4% value of reading (or +/-0.2% value of reading) With Forward/Reverse flowrate measurement function It has electrode cleaning function

SPECIFICATION

Size:Electrode & Grounding:

10A,10,15,20, 25,32,40,50,65,80,100,125Stainless Steel 316L

150,200,250,300,350,400,450,500,600Hastelloy B

700,800,900,1000,1200,1400,1600Hastelloy C

1800,2000 mmTitanium

Measuring Range:Tantalum

Velocity 0 - 0.25 m/s min.Platinum

0 - 12 m/s max.Tungsten Carbide

Material:Grounding Electrode:

Measuring TubeDN10A/10: use Grounding Ring *1pc

Stainless Steel 304DN15-2000: 3 Electrodes

FlangeProcess Connection:

Carbon Steel (Standard)Flange

Stainless Steel 304 (Option)Flange Type:

Stainless Steel 316, 316L (Option)JIS 10K / JIS 20K / JIS 40K

Coil HousingANSI 150# / ANSI 300# / ANSI 600#

Carbon Steel (Standard)DIN PN 10 / PN 16 / PN25 / PN 40

Stainless Steel 304 (Option)Grounding Resistance:

Stainless Steel 316,316L (Option)Must be less than 10

Liner:Accuracy:

Polyurethane (25-400 mm)+/-0.4% of reading (Velocity¡Ý0.5 m/s)

Neoprene (50-2000 mm)+/-0.0025 m/s (Velocity < 0.5 m/s)

FEP (10A-300 mm)+/-0.2% of reading

PTFE (10A-2000 mm)(Suitable for AMC3200/3200E converter )

PFA (10A-300 mm)Temperature:

Protection Class:-10 ~ +60 oC(Polyurethane, PU)

Junction box IP67, Body IP68-20 ~ +70 oC(Neoprene)

IP 68 (Submersible)-40 ~ +120 oC(PTFE 3/8"to 10")

Conductivity:-40~+140 oC(PTFE 3/8"to6", FEP 3/8"to12")

More than 5 uS/cm-40~+180 oC(PTFE 3/8"to3", PFA3/8"to12")

Explosion Proof:Ambient Temperature:

Exd(ib)ibqIIBT5 -25 to +60 oC

(with AMC3200 only)Max. Pressure:

Cable Entry:350 Kg/cm2

Standard :PG11 Option:1/2"NPTF

AMF500 Series

AMF500 Series is a wafer type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 25 to 200 mm. AMF500 is widely used for tap-water, waste water, food & beverage, pulp & paper and many other industrial fluid. AMF500 Series electromagnetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic flowmeter.

FEATURES

Light and compact version Flow Velocity range: 0-12 m/s, precise in low flow applications It comes any flanges such as ANSI, DIN, JIS... etc Excellent for high pressure application Protection class: IP68 available; sensor submersible FEP Liner is suitable for vacuum tube High accuracy of +/-0.4% value of reading (or+/-0.2% value of reading) With Forward / Reverse flowrate measurement function It has electrode cleaning function

SPECIFICATION

Size:Cable Entry:

25, 32, 40, 50, 65, 80, 100, 125, 150, 200 mmStandard :PG11 Option:1/2"NPTF

Measuring Range:Ambient Temperature:

Velocity 0-0.25 m/s min.

-25 to +60 oC

0-12 m/s max.Process Connection:

Material:Wafer

Measuring TubeFlange type:

Stainless Steel 304JIS 10K / JIS 20K / JIS 40K

Coil HousingANSI 150# / ANSI 300# / ANSI 600#

Carbon Steel (Standard)DIN PN 10 / PN 16 / PN25 / PN 40

Stainless Steel 304 (Option)Grounding Resistance:

Stainless Steel 316 (Option)Must be less than 10

Liner:Accuracy:

PTFE, FEP+/-0.5% read-out values (Velocity >=0.5 m/s)

Protection Class:+/-0.2% read-out values

Junction box IP67, Body IP68(Suitable for AMC3100/AMC3200E converter only)

IP 68 (Submersible)+/-0.0025 m/s (Velocity < 0.5 m/s)

Conductivity:Temperature:

More than 5 uS/cm

-40 to +180 oC

Electrode & Grounding:Max. Pressure:

Stainless Steel 316L16 Kg/cm2 (Standard)

Hastelloy B40 Kg/cm2 (Option)

Hastelloy CExplosion Proof:

TitaniumExd(ib)ibqIIBT5

Tantalum(with AMC3200 only)

Tungsten Carbide

Platinum

Alia Flow Meter Sanitary Flow Meter Food Grade Flow Meter Electromagnetic Flowmeter AMF601 Series is a sanitary type electromagnetic Flowmeter ideal for conductive liquids. It comes in sizes from 25 to 100 mm. The AMF601 is widely used for drink water, Milk , food & beverage juice and many other industrial fluid. AMF601 Series electromagnetic flowmeter could be used in compact or separate model with AMC Series converter ofelectromagnetic Flowmeter. FEATURES

  • Light and compact version

  • Flow Velocity range:0-12 m/s, with precisely measure for low flow applications

  • IDF Tri-Clamp or Union screw Connection

  • It excellent for high pressure application

  • Protection class: IP68 is available, and the sensor can sink into the water

  • PTFE Liner is suit for vacuum tube

  • High accuracy of +/-0.4% value of reading (or+/-0.2% value of reading)

  • With Forward/Reverse flowrate measure function

AMF900 Series Electromagnetic Flow Meter AMF900 Series is a flange type Electromagnetic Flow meter ideal for conductive liquids. It comes in sizes from 6 to 2000mm. AMF900 electromagnetic flow meter is widely used for tap-water, waste water, food & beverage Pulp & Paper and many other industrial fluid. AMF900 Series electromagnetic flow meter could be used in compact or separate model with AMC Series converter of electromagnetic Flowmeter.

Alia Electromagnetic Flow Meter

FEATURES

Various liner and electrode can be selected to satisfy most industrial applications Flow Velocity range:0-12 m/s, with precisely measure for low flow applications It comes any flanges such as ,ANSI, DIN, JIS... etc Excellent for high pressure application Protection class: IP68 is available, and the sensor can sink into the water FEP Liner is suit for vacuum tube High accuracy of +/-0.4% value of reading (or +/-0.2% value of reading) With Forward/Reverse flowrate measure function

SPECIFICATION

Size:Electrode & Grounding:

6,10,15,20, 25,32,40,50,65,80,100,125Stainless Steel 316L

150,200,250,300,350,400,450,500,600Hastelloy B

700,800,900,1000,1200,1400,1600Hastelloy C

1800,2000 mmTitanium

Measuring Range:Tantalum

Velocity 0 - 0.25 m/s min.Platinum

0 - 12 m/s max.Tungsten Carbide

Material:Cable Entry:

Measuring TubePG11

Stainless Steel 304Ambient Temperature:

Flange

-25 to +60 oC

Carbon Steel (standard)Process Connection:

Stainless Steel 304(Option)Flange

Stainless Steel 316,316L(Option)Flanges Type:

Coil HousingJIS 10K / JIS 20K / JIS 40K

Carbon Steel (standard)ANSI 150# / ANSI 300# / ANSI 600#

Stainless Steel 304(Option)DIN PN 10 / PN 16 / PN25 / PN 40

Stainless Steel 316,316L(Option)Grounding Resistance:

Liner:Must be less then 10

Polyurethane(25-600 mm)Accuracy:

Neoprene(50-2000 mm)+/-0.4% read-out values(Velocity>=0.5 m/s)

FEP(6-300 mm)+/-0.0025 m/s (Velocity < 0.5 m/s)

PTFE(25-800 mm)+/-0.2% read-out values

PFA(6-300 mm)(suit for AMC3100 Converter only)

IP 68Temperature:

IP 68 (Submersible)

-10 ~ +60 oC (Polyurethane,PU)

Conductivity:

-20 ~ +70 oC (Neoprene)

More than 5 uS/cm

-40 ~ +180 oC (FEP)

Explosion Proof:

-40 ~ +180 oC (PTFE/PFA)

Exd(ib)ibqIIBT5 (with AMC3100 only)Max. Pressure:

350 Kg/cm2

Related Posts

See All
Recent Posts
Archive
Search By Tags
Follow Us
  • Facebook Basic Square
  • Twitter Basic Square
  • Google+ Basic Square
bottom of page